B. INSTRUCTIONS FOR USE RM182B

The Controls

:

Controls are located at the top of the refrigerator.

1. Control Panel

:

Fig. 1 Page 1

___

“A” -

"B" -

"C" _

Air Pump and Piezo Lighter

Safety Valve

Thermostat for Gas and 120

the unit runs continously)

Voltage Selector Switch

Gas Shut-Off Valve

Flame Pilot Sight Peep

Volt Operation (12 volt has no thermostat,

2. Gas Operation - Lighting the Burner

_________ ____________ ____ ___________

1. Place Voltage Switch "D" (Fig. 1) on position

,

then place Gas

Valve "E" (Fig. 1) to position

I

2. Turn thermostat "C" (Fig. 1) to maximum

3. Depress button "B" (Fig. 1) for 20 seconds to let gas flow to burner

4. Release button "B" and pump knob "A" (Fig. 1) 20 times DO NOT

pump

until click is heard, stop short of this position.

5. Once again, press button "B" (Fig. 1) and hold, simultaneously pump

knob “A” (Fig. 1) several times until noticable click is heard (this

is Piezo Lighter).

6. When burner is lit, hold button "B' (Fig. 1) for at least lo seconds.

7. Flame may be observed through pilot sight peep "F" (Fig. 1) and ice

tray should show signs of cold after two hours.

3. Electrical Operation

_______

1.

Place Gas Valve "E" (Fig. 1) to position 0

2. Place Voltage Selector Switch "D" (Fig. 1) to the appropriate voltage.

NOTE: The 12 volt circuit is not thermostatically controlled, Be-

cause of an inserted relay, the 12 Volt operation is only possible

if the car ignition is switched on.

4. Temperature Control

_______ _______________

With the thermostat knob "C" (Fig. 1) set at the middle position, the

cabinet will automatically maintain a suitable temperature for ordinary

food storage. Usually, no further adjustment will be necessary, but in

hot weather, or when more cooling is required, the knob "C" (Fig. 1)

must be turned to a higher position.

If less cooling is required, the knob should be turned to a lower po-

sition.

If knob "C" (Fig. 1) is turned completely to the left, the 120 Volt

circuit is switched off. During gas operation the same position corres-

ponds to Minimum Cooling.