3 phy, 1 management interface, 4 private i2c bus – Artesyn ARTM-9405 16x10GbE Installation and Use Guide (May 2014) User Manual

Page 46: Table 4-9, Private i2c port, Private i2c bus, Functional description

Advertising
background image

Functional Description

ARTM-9405 16x10GbE Installation and Use (6806800P45F)

46

4.3

PHY

The ARTM-9405 uses four NetLogic NLP10142 to provide 2x QSFP interfaces and 8x SFP+
interfaces on the face plate.

4.3.1

Management Interface

The Netlogic NLP10142 supports IEEE802.3 Clause 45 station management interface. The
MDC/MDIO signals are connected to Marvell switch device of the ATCA-9405 front board.

4.4

Private I2C Bus

Two private I2C bus on the ARTM-9405 16x10GbE are implemented as a bit banging interface
at the MMC.

Number of power draw
levels

1

The amount of possible power levels

Early Power Draw Levels,
Watt

-

Complete early power level including MMC

Steady state Power Draw
Levels, Watt

?

Complete steady power consumption including IPMC
and RTM

Transition from early to
steady levels, sec

0s

-

Table 4-8 Power Configuration (continued)

Item

Value

Description

Table 4-9 Private I2C Port

MMC Port

Private I2C Signal

PG.4

RTM_PVT_I2C_0_SCL

PG.2

RTM_PVT_I2C_0_SDA

PA.7

RTM_PVT_I2C_1_SCL

PA.1

RTM_PVT_I2C_1_SDA