PEI Status Codes

Table 5-33 PEI Status Codes

Status Code

Description

Progress Codes

0x10

PEI Core is started.

0x11

Pre-memory CPU initialization is started.

0x12

CPU pre-memory initialization (CPU module specific).

0x13

CPU pre-memory initialization (CPU module specific).

0x14

CPU pre-memory initialization (CPU module specific).

0x15

Pre-memory North Bridge initialization is started.

0x16

Pre-memory North Bridge initialization (North Bridge module
specific).

0x17

Pre-Memory North Bridge initialization (North Bridge module
specific).

0x18

Pre-Memory North Bridge initialization (North Bridge module
specific).

0x19

Pre-memory South Bridge initialization is started.

0x1A

Pre-memory South Bridge initialization (South Bridge module
specific).

0x1B

Pre-memory South Bridge initialization (South Bridge module
specific).

0x1C

Pre-memory South Bridge initialization (South Bridge module
specific).

0x1D - 0x2A

OEM pre-memory initialization codes.

0x2B

Memory initialization. Serial Presence Detect (SPD) data reading.

0x2C

Memory initialization. Memory presence detection.

0x2D

Memory initialization. Programming memory timing information.

0x2E

Memory initialization. Configuring memory.

0x2F

Memory initialization (other).