3 environmental and power requirements, 1 environmental requirements, Table 2-1 – Artesyn RTM-ATCA-7350 Installation and Use (September 2014) User Manual
Page 20: Environmental requirements
Hardware Preparation and Installation
RTM-ATCA-7350 Installation and Use (6806800H30G)
20
3. Remove the desiccant bag shipped together with the blade and dispose of it
according to your country’s legislation.
2.3
Environmental and Power Requirements
The following environmental and power requirements are applicable to the board.
2.3.1
Environmental Requirements
The product is thoroughly inspected before shipment. If any damage occurred during
transportation or any items are missing, please contact our customer's service immediately.
Table 2-1 Environmental Requirements
Requirement
Operating
Non-Operating
Temperature
+5ºC (41ºF) to +40ºC (104ºF) (normal operation)
according to NEBS Standard GR-63-CORE
-5ºC to +55ºC (short term operation) according to
NEBS Standard GR-63-CORE
-40ºC (-40ºF) to +70ºC
(158ºF) (may be further
limited by installed
accessories)
Temp. Change
+/- 0.25ºC/min or 15ºC/h (59ºF/h) according to
NEBS Standard GR-63-CORE
+/- 0.25ºC/min or 15ºC/h
(59ºF/h)
Rel. Humidity
5% to 85% non-condensing according to Artesyn -
internal environmental requirements
5% to 85% non-condensing
according to Artesyn -
internal environmental
requirements
Altitude
<= 4000m