Avalon Firestyles Gas/Pellet Remote Thermostat User Manual

Compatibility, Packing list, Installation warnings

Advertising
background image

Wall Thermostat

SKU 99300650

Page 1 of 3

2/2/11 - 17601040

© Travis Industries, Inc.

Compatibility

• All Travis Gas Stoves
• 33 DVI Insert
• 31 DVI Insert
• 564 SS and DF

• 864 TRV, ST, and HO
• All Travis Pellet Stoves or Inserts

Packing List

• Thermostat
• Thermostat Wire (20’)
• (2) Screws (for attaching thermostat)

Installation Warnings

! Shut off power to the appliance and allow it to cool prior to installation.

! This kit must be installed by a qualified technician.

! Do not connect 110 VAC to the gas control valve or on/off switch on gas heaters or the thermostat

posts on pellet heaters.

Follow the instructions on the following pages for the type of model being addressed.

Wire Connection - Pellet Heaters

Attach the thermostat wire to the circuit board.

b

Swing the

panel

open.

d

a

Phillips

Screwdriver

Open the hopper lid and remove the

screw holding the right panel in place.

Route the wires up to the circuit

board and attach the quick-connects

to the thermostat posts (orientation

does not matter).

Bundle up any excess wire with a

lock-tie to prevent it from contacting

any hot or moving parts

If necessary, attach the

pellet stove connector

wires to the ends of the

receiver wires.

c

Advertising