Extra room power heat duct instructions – Avalon Firestyles Extra Room Power Heat Duct User Manual

Page 7

Advertising
background image

Extra Room Power Heat Duct Instructions

SKU 98500769

Page 7 of 11

12/2/13 - 17601067

© Travis Industries, Inc.

Wiring Diagram – Internal Thermodisk Using Extension Module
(Xtreme 6020 V1 (2012 or earlier), 36 CF ST/Pier, and 1080 CF)

Snap Disk

(inside fireplace)

Heat Duct

Blower

Fireplace Junction Box

Molex

Connector

Molex

Connector

Black

Black

Black

Black

Blower Junction Box

White

Green

White

Green

Black

Black

Romex

Connector

White

Green

Molex

Connector

White

Green

Black

FAN

Fireplace Control Box

120V Extension

Module

Wiring Diagram - Internal Thermodisk without Extension Module
(36 CF ST/Pier and 1080 CF)

Rheostat

Junction Box

Snap Disk

(inside fireplace)

Power Supply

Common

(white)

Ground

(green)

Heat Duct

Blower

Fireplace Junction Box

Receptacle

Molex

Connector

Black

Black

Black

Black

Hot

(black)

White

Green

Blower Junction Box

White

Green

White

Green

Black

Black

Romex Connectors

Molex

Connector

Fireplace Control Box

Advertising