Extra room power heat duct instructions – Avalon Firestyles Extra Room Power Heat Duct User Manual
Page 7
Extra Room Power Heat Duct Instructions
SKU 98500769
Page 7 of 11
12/2/13 - 17601067
© Travis Industries, Inc.
Wiring Diagram – Internal Thermodisk Using Extension Module
(Xtreme 6020 V1 (2012 or earlier), 36 CF ST/Pier, and 1080 CF)
Snap Disk
(inside fireplace)
Heat Duct
Blower
Fireplace Junction Box
Molex
Connector
Molex
Connector
Black
Black
Black
Black
Blower Junction Box
White
Green
White
Green
Black
Black
Romex
Connector
White
Green
Molex
Connector
White
Green
Black
FAN
Fireplace Control Box
120V Extension
Module
Wiring Diagram - Internal Thermodisk without Extension Module
(36 CF ST/Pier and 1080 CF)
Rheostat
Junction Box
Snap Disk
(inside fireplace)
Power Supply
Common
(white)
Ground
(green)
Heat Duct
Blower
Fireplace Junction Box
Receptacle
Molex
Connector
Black
Black
Black
Black
Hot
(black)
White
Green
Blower Junction Box
White
Green
White
Green
Black
Black
Romex Connectors
Molex
Connector
Fireplace Control Box