Lopi Front Blower

Installation Instructions

 

 

Page 1 of 2

17601771.docx — 11/15/12

© Travis Industries, Inc.

Compatibility

SKU 99000123 – Answer, Revere, 1750 Insert, 1250 Insert 
SKU 99000126 – Freedom 

Items Required

 3/8” Nutdriver 
 Phillips Screwdriver 
 Slip Joint Pliers (if switching power cord to left side) 
 

To Switch the Power Cord to the Left Side:

Use a pair of slip‐joint pliers to disconnect the strain relief which holds the power cord in place. With the 
power cord slackened, the Molex connectors that attach the power cord to the blower assembly may be 
disconnected. Pry the button plug from the left side of the blower assembly and insert it into the hole 
on the right side. Pull the left side Molex connector out from behind the deflection plate and cut the 
nylon tie that holds the wire back. Insert the Molex connector on the power cord through the hole on 
the left side of the blower assembly and attach it to the left side Molex connector. Route the wire 
directly behind the blower cage. Place the strain relief over the power cord (it should be in the same 
location on the power cord as before – approximately 2” from where the wires split). Insert the strain 
relief into the hole on the left side until the strain relief locks in place. Make sure the power cord, wires, 
or Molex assembly do not protrude into the blower opening. 

 

 
 

 