M L I Q U I C K R E F E R E N C E

Avery Dennison’s MONARCH LANGUAGE INTERPRETER™ (MLI™) and this Quick Reference

are intended to help you use the MONARCH® 9855™ printer, which was set up for use with ZIH

Corp.’s ZPL II®. If you have any questions about using a MONARCH® printer with these data

streams, please contact your Monarch representative.
This Quick Reference lists the ZPL II® commands that the 9855 printer can interpret with any

special notes, if applicable.
Note:

Information in this document supercedes information in previous versions. Check our

Web site (

www.monarch.com

) for the latest release and documentation information.

S e l e c t i n g t h e I n t e r p r e t e r

When you turn on the printer, you must set

the interpreter to MLI or MPCL to print non-

MLI data streams.

1.

From the Main Menu, select Setup.

2.

Press  or  until you see

SETUP

Interpreter

3.

Press Enter/Pause.

INTERP

RETER

MPCL

4.

Press  to see MLI, then press
Enter/Pause

.

The printer reboots automatically after

selecting an interpreter. This process

may take several seconds.

When you print test labels with MLI set as

the interpreter, the model number appears

as M9855MLI.

O v e r v i e w o f D i f f e r e n c e s

ZPL II® formats have a reference point at

the upper left-hand corner of the printed

label. The MONARCH 9855 printer’s

reference point is at the lower left-hand

corner of the printed label.

The MONARCH 9855 printer is center-

justified and the maximum supply width is

4.2 inches wide. The maximum image

size is 4.0 inches. The printer must be

set for the width of the loaded supply.

See “Entering the Supply Width,” for

more information.

The MONARCH 9855 printer calibrates

when it receives the first byte of data

from the host or whenever the printhead

is closed.

The MONARCH 9855 printer using the

MONARCH LANGUAGE

INTERPRETER™ only reports the

following errors: 409-426; 497, 499, and

703-793. Refer to your printer’s
Operator’s Handbook

or the optional

Packet Reference Manual

for

descriptions of these errors.

E n t e r i n g t h e S u p p l y W i d t h

The printer must be set for the width of the

loaded supply. Follow these instructions

any time you load supplies with a different

supply width. After you load supplies, select
Supply Width

from the printer’s Main Menu.

You see

Supply

Width

[203/812]:

+812

1.

Enter the supply width in dots, where

one inch equals 203 dots. For example,

two-inch wide supply equals 406 dots.
Feed/Cut

acts as a toggle switch to

change the value by 10 or 1. To

make the supply width 711 for 3.5-

inch wide supply (from the default of

812), press  once (the display

shows 811). Press Feed/Cut once

and then press  ten times (the

display shows 711).

2.

After you display the value you want,

press Enter/Pause. You return to the

Main Menu.

Advertising