Ep cylinder dwell time (apt1), Blowing time (apt2), Delay time (apt3) – Avery Dennison ALS 380 User Manual

Page 73: Als 380, Peration, Pplicator, Optional

Advertising
background image

71

4

O

PERATION

4.6 A

PPLICATOR

(

OPTIONAL

)

ALS

380

EP cylinder dwell time

(APT1)

– Dwell time for the EP cylinder

In the extended menu:

Call up the APT1 function.

Set the desired value.

– Settings are possible in 1 ms steps:

1 ... 7500 ms

Confirm the setting using the ENTER key and exit
the function.

Blowing time

(APT2)

When using a blowing applicator:
– Dwell time for blowing the label on the product

In the extended menu:

Call up the APT2 function.

Set the desired value.

– Settings are possible in 1 ms steps:

1 ... 7500 ms

Confirm the setting using the ENTER key and exit
the function.

Delay time

(APT3)

When using an EP applicator:
– Delay of the signal air blow.

The signal controls the air blow which blows the la-
bel onto the underside of the applicator. The value
for APT3 is the delay between the start of label dis-
pensing and activation of the air blow.

In the extended menu:

Call up the APT3 function.

Set the desired value.

– Settings are possible in 1 ms steps:

1 ... 5000 ms

Confirm the setting using the ENTER key and exit
the function.