Avery Dennison 9450 RASCAL Rev.A 1/95 Quick Reference User Manual
Rcl quick reference, Change communication parameters (^a), Clear error status (^c)
TC9450PQR Rev. A 1/95
1995 Monarch Marking Systems, Inc. All rights reserved.
Following are summaries of each RCL (RASCAL
printer Control Language)
command. They appear in alphabetical order.
Change Communication Parameters (^A)
The Change Communication Parameters command changes the printer’s baud rate,
parity, word length, and flow control.
^A¦5¦N¦8¦X¦^
Flow Control X (XON/XOFF), C (RTS/CTS), or D (DTR).
Word Length 7 (use with even parity) or 8 (use with none parity).
Parity N (None-- use with word length 8) or E (Even-- use with word length 7).
Baud Rate 2 (1200), 3 (2400), 4 (4800), 5 (9600), 6 (19200), or 7 (38400).
Command Identifier
Clear Error Status (^C)
The Clear Error Status command clears batch errors from memory.
^C¦^
Command Identifier
Delete Batches (^F)
The Delete Batches command removes all batches immediately, or it removes the
current batch after it prints the next complete label.
^F¦A¦^
Function A (delete all batches) or C (delete the current batch).
Command Identifier
RCL Quick Reference