Howtorfid – Avery Dennison RFID User Manual

Page 39

Advertising
background image

HowToRFID

Revision: 13

Date: 31 August 2009

Page 39 of 53

5.3.4.2

#VR/T – Reading data from tag

Use #VR/T/<expression> command. For details see [A0164].

5.3.4.3

#VW/T – Writing data to the tag

Use the #VW/I/<expression> command. For details see [A0164].

5.3.5

Sending data (read from tag) to an interface

Sending data that was written to the tag or read from the tag back to the host requires the use of a variable + two
explicit commands

1) Define a variable using #VDT

2) Read data from tag using #VR/T (or write data to tag using #VW/T)

3) define response format and point on time / condition (trigger) with

#SI command

4) send data with

#VW/I command using the variable defined in 1)

5.3.5.1

#SI – Response format definition

Definition

There is a response string made of header h and requested data that is send back to the
host via EasyPlug Interface. If parameter n is different from zero the return string is
trimmed to byte count n. If respond string is less than n bytes it is filled with blanks (hex
code 0x20), otherwise respond string is truncated to fit into n bytes.

Command must be placed between #ER and #Q!

Syntax

#SIr/n/h#G

RFID printer

#SI

r/n/h#G

r = int

logical point in time concerning print control that defines when to send data
(trigger point)

1 = at start of a new EasyPlug format

2 = at restart of a previous EasyPlug format (#Q without #ER)
3 = at start of a single label operation
4 = at start of RFID operation
5 = at end of successful RFID operation(s); if read/write operations fail the

trigger doesn’t fire

6 = at start of the real print process
7 = at end of the real print process
8 = at end of a single label operation (label printed without error)
9 = at end of an EasyPlug format (#Qn label printed)
10 = at any motion control error
11 = at any RFID error (tag read or tag write error); triggered together with the

Bad Tag Signal