PRESSURE Ø

INJECTOR

THERMAL

CAPACITY

GAS TYPE

mbar

BURNER

1/100

mm

Nominal W

CONSUMPTION

Triple-

crown

141 3500

333

Rapid 129 3000 286

Semi-

rapid

101 1750

167

Natural

gas – G20

20

Auxiliary 77

1000 95

l/h

Triple-

crown

94 3500

254

Rapid 87 3000 218

Semi-

rapid

66 1750

127

LPG –

G30/G31


28-30/37

Auxiliary 50

1000 73

g/h

o

Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.

o

IMPORTANT: The minimum flow adjustment process must
be completed before the appliance is next used.


Minimum flow adjustment for hob gas taps.


All work must be carried out by a GASSAFE
registered engineer.


IMPORTANT: Always isolate the hob from the electricity supply
before changing the injectors and/or adjusting the minimum
flow of the burners.

o

Switch the burner on and set the knob at the minimum position.

o

Remove the knob from the tap and place a small bladed
screwdriver in the centre of the tap shaft.