30

CP62xx-xxxx-0030/-0035/-0040


Technical data

Dimensions

Dimensions (W x H x D): see section

Assembly dimensions

.

Operation in areas that are
subject to explosion hazard

The Industrial PC must not be used where there is a risk of explosion.

The following conditions must be observed during operation:

Environmental conditions

Ambient temperature:

0 to 55°C

Atmospheric humidity:

Maximum 95%, non-condensing

Shock resistance

Sinusoidal vibration:

(EN 60068-2-6)

10 to 58 Hz:

0.035 mm

58 to 500 Hz: 0.5 G (~ 5 m/ s

2

)

Impact:
(EN 60068-2-27/ 29)

5 G (~ 50 m/ s²), duration: 30 ms

Protection class

Front side:

IP65

Rear side: IP20

Power supply
24 V

DC

power pack

Supply voltage: 24

V

DC

(22 – 30 V

DC

)

Power consumption:

approx. 59 W with 12“ display

approx. 70 W with 15“ display

approx. 77 W with 19“ display

approx. 99 W with 24“ display

If operated with UPS:

additional 30 W (while charging)

additional 44 W (UPS-output max.)

EMC compatibility

Resistance to interference: conforms to EN 61000-6-2

Emission of interference: conforms to EN 61000-6-4

Transport and storage

The same values for atmospheric humidity and shock resistance are to be
observed during transport and storage as in operation. Suitable packaging
of the Industrial PC can improve the resistance to impact during transport.
The ambient temperature during storage and transport must be between
-20°C and +65°C.

Pixel errors

Note

Pixel errors in the TFT display are production-caused and represent no
complaint-reason!


Approvals

FCC: Federal Communications Commission
Radio Frequency Interference Statement

FCC Approval for USA

This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own
expense.

FCC: Canadian Notice

FCC Approval for Canada

This equipment does not exceed the Class A limits for radiated emissions
as described in the Radio Interference Regulations of the Canadian
Department of Communications.

Advertising