Troubleshooting, Fault correction, Troubleshooting 16 – BECKHOFF CP68xx User Manual

Page 18: Can be used to determine the measures to be taken

Advertising
background image

Troubleshooting

Troubleshooting

Please also refer to chapter

General Notes

.

i

Note

Pixel errors in the TFT display are production-caused and represent
no complaint-reason!


Fault correction


Fault Cause Measures
The Control Panel shows no
function when the Industrial PC has
been started

No power supply to Control Panel

Cable not connected

Check power supply cable

1. Correctly connect cable
2. Call Beckhoff Service

The Industrial PC does not boot
fully

Floppy disk or CD in the drive


Hard disk damaged (e.g. by
switching off while software running)

Setup settings are incorrect

Other cause

Remove floppy disk or CD
and press any key

1. Boot with boot diskette
2. Start SCANDISK

Check the setup settings

Call Beckhoff Service

Computer boots, software starts,
but control does not operate
correctly

The cause of the error is in the
software or in parts of the
equipment outside the control panel

Call the manufacturer of the
machine or the software

Floppy disk or CD access error

Faulty disk or CD


Faulty disk drive

Check disk or CD in another
drive

Call Beckhoff Service

The Control Panel has only partial
function, or only functions some of
the time, for instance the picture is
dark or absent

Faulty fluorescent bulb in the
display


Defective components in control
panel

Replace fluorescent tube in
the display in accordance
with description

Call Beckhoff Service.

16

CP68xx

Advertising