BECKHOFF AX2090-ND50 User Manual

Technical documentation, Foreword, Safety

Advertising
background image

Mains choke AX2090-ND50 (AX5160 – AX5193)

BECKHOFF

Drive Technology


Technical Documentation

Beckhoff Automation

Hülshorstweg 20

Version:

1.0

33415 Verl

Date:

06.01.2015

Germany

Language: EN

Order-No.: TDmlAX-2090-ND50-0000-401

Phone: +49(0)5246/963-0

Fax: +49(0)5246/963-198

[email protected]

www.beckhoff.com

Please read carefully before commissioning!

Foreword

Appropriate use

The mains chokes of the series “AX2090-ND50“ are exclusively intended for application in the control cabinet as

power supply unit of the AX5000. The chokes are installed together with the servo drive as components in electrical

systems and machinery and may only be used in this way.

Safety

Safety rules

The responsible staff must ensure that the application or use of the products described satisfy all the requirements for

safety, including all the relevant laws, regulations and guidelines

DANGER

Serious risk of injury through electric shock!
Even when the AX5000 is disconnected from the mains voltage, dangerous voltage continues to be

present at the "X02" terminals of the DC link: AX5160/AX5172 =

15 min., AX5190/AX5191 = 30 min. and

AX5192/AX5193 =

45min.. Never touch the terminals within this period.

WARNING

Risk of injury!
Electronic equipment is not fail-safe. The machine manufacturer is responsible for ensuring that the

connected motors and the machine are brought into a safe state in the event of a fault in the drive system.

Personnel qualification

This description is only intended for trained specialists in control, automation and drive engineering who are familiar

with the applicable national standards. Knowledge of machine safety legislation is compulsory.

Technical data

AX2090-ND50-

Data

0060

0072

0090

0110

0143

0170

Rated voltage [V AC]

460 -25% / +10%

Rated frequency [Hz]

50 / 60

Rated current [A]

60

72

90

110

143

170

Ambient temperature [°C]

45 (with power reduction 60)

Relative air humidity

15%...95%, Condensation not permitted

Permissible contamination

P2 to EN 61558-1

Storage temperature [°C]

-25...+70

Mounting height [m]

1000 (with power reduction 4000)

(6% / 1000m)

Protection

IP00

Inductance [mH]

0,25

0,20

0,16

0,13

0,10

0,09

Weight [kg]

7

10

13

15

25

25

Listings

UL/CSA

Advertising