M1400 Parallel Input /Output

Beckhoff II/O-System

Date : 26.7.94

Version : 2.0

Page 9 of 16

The following modul configuration is possible by setting jumpers 4 to 7 :

Fast Inputs M1400 (Interrupt Inputs)

Jumper 4

Fast input II3 :
If jumper connection betwenn port D0.3 and XILINX II3 is
established Fast input is activated

Jumper 5

Fast input II2 :
If jumper connection betwenn port D0.2 and XILINX II3 is
established Fast input is activated

Jumper 6

Fast input II1 :
If jumper connection betwenn port D0.1 and XILINX II3 is
established Fast input is activated

Jumper 7

Fast input II0 :
If jumper connection betwenn port D0.0 and XILINX II3 is
established Fast input is activated

Power Supply

There are the following connections for power Supply :

(1)

two pole plug connection for the controller (X10 Pin1+2)

(2)

two pole plug connection for outputs (X20 and X30 Pin1+2)
( 16 outputs )

(3)

two pole plug connection for inputs (X21 and X31 Pin1+2)
(16 inputs)

(4)

two pole plug connection for ground (X22 and X32 Pin1+2)

Advertising