Maintenance – Beisler 1265-4 User Manual

Page 54

Advertising
background image

Service Instructions Automatic Single-Head Serging Machine 1265-4

Beisler GmbH

C-18

C.5

Maintenance

Fig. 9: Settings for the pneumatic stop:

1. Set the height position of the pneumatic stop. Loosen the locating

screw 7 at the cylinder bracket block. Place the stop plate 3 onto

the stitch plate 8 and retighten the locating screw.

2. Adjust the lateral distance to kettup knife and pres-

sure foot. The distance A (between kettup knife 2

and stop plate 3) should be approx 0.2-0.3 mm.

Set the distance by rotating the knurled screw 4.

3. Aligne the pressure foot 1 at the stop 3. Loosen

the pressure foot locating screw, push the pressu-

re foot close to the stop and retighten the locating

screw. The sewing foot should be positioned at

distance B of approx 0.5 mm from the kettup kni-

fe.

4. The advance and withdrawal

rates of the stop are set using

the pressure cylinder throttles.

Set the advance rate using

throttle 7, set the withdrawal

rate using throttle 5.

Fig. 9