Beisler 1225-5 User Manual

Page 29

Advertising
background image

Adjusting the holding stamp

Via this parameter the holding stamp is adjusted.

Parameter 15:

Time when the stamp lowers.

Setting range:

0 …20

Parameter 16:

Time how long the warp separator remains switched
on.

Setting range:

0 …100

Parameter 17:

Switch the stacker on or off

Setting range:

0 / 1

Parameter 47:

Time of stacker movement

Setting range:

0 …2000

Parameter 57:

Time how long the holding stamp is down

Setting range:

0 …2000

Altering the machine parameters

Parameter 30:

Set the main speed

Setting range:

0 …8500

Parameter 31:

Switch manual sewing on or off

Setting range:

0 / 1

Parameter 32:

Number of stitches how long the table blowing
remains switched on

Setting range:

0 …400 stitches

Parameter 34:

Number of stitches until the contour guide
lowers

Input:

0 …400 stitches

Parameter 44:

Number of stitches until the contour guide
lowers

Input:

0 …200

Parameter 60:

Softstart speed
Setting range:

500 ...5000

Parameter 61:

Switch the softstart on or off

Setting range:

0 / 1

Parameter 76:

Switch the start via light barrier on or off

Setting range:

0 / 1

Parameter 77:

Switch the autostart on or off

Setting range:

0 / 1

Parameter 78:

Number of stitches when the autostart starts

Setting range:

0 ...400 stitches

Parameter 98:

Switch the lining clamp on or off

Setting range:

0 / 1

25

1

Advertising
This manual is related to the following products: