Save these instructions, Troubleshooting guide – Besa Lighting 8 Ft Monorail (Monorail 12V) User Manual

Page 3

Advertising
background image

Monorail Troubleshooting, Rev.6 11-10

TROUBLESHOOTING GUIDE

12V Monorail System

i.

Loosen the Set Screws on the Power Adapter, and disconnect

the Power Adapter completely from the Power Supply Canopy.

ii. Check for continuity by placing a probe on each monorail conductor.

If the tester does NOT light, proceed to Step 3 on next page.

iii. If the tester lights, remove any Quick Connect Pendants or Fixtures

by unthreading the Quick Connects from the Quick Connect Adapters.

The Quick Connect Adapters must remain on the Rail.

iv. Check for continuity by placing a probe on each monorail conductor.

If the tester does NOT light, proceed to Step 2 below.

v. If the tester lights, it is indicating a short circuit which is unintended. The most common reason for a Rail short is a missing

Contact your local Besa Distributor or Besa Customer Service if any replacement parts are needed.

Set Screws

on both sides

Power

Adapter

Power Supply Canopy

2. It is possible that a short or open circuit exists at the Quick Connect Jack.

NOTE: You will need a continuity tester or multi-meter to check the

Quick Connect Jack.

i.

Remove the lamp. Place a probe on the base of the collar and the other on the

end of the Quick Connect Jack, per Continuity Test #1. If the tester lights, it is indicating

a short circuit, refer to the Quick Connect Repair section on next page.

If the tester does NOT light, move to the next step to check for an open circuit.

ii. Reinstall lamp and perform the same continuity test as above.

If the tester lights, then the Quick Connect Jack has been installed properly

and you can proceed to Step 3 on next page. If the tester does NOT light,

move to the next step to check for an open circuit.

iii. Perform an additional continuity test with the probes shown in Continuity Test #2.

If the tester does NOT light, the Quick Connect Jack part is defective and needs to be

replaced. If the tester does light, refer to the Quick Connect Repair section on next page.

A) Problem: The system does not turn on

(or 150 watts when using the R12-SA150 Power Supply), then check for a short circuit condition at the Rail.

NOTE: You will need a continuity tester or multi-meter to check for shorts.

Check for clear washer

behind screw head

middle section to eliminate

all metal fragments.

Power

Adapter

Rail Adapter

Live Rail

Connector

Connector to short. Ensure Rail sections

HINT:

If the short is not visually obvious,

it is best to remove individual

components until the source

of the short is revealed.

Continuity Test #1

Probe

Probe

Continuity Test #2

Probe

Probe

For Replacement Parts, Contact your local Besa Distributor or Besa Customer Service.
Besa Customer Service
Email: [email protected] Phone: 1-866-917-8760

SAVE THESE INSTRUCTIONS

6695 Taylor Rd. Blacklick, OH 43004

www.besalighting.com

Advertising