6. Changing the infrared lamp

The device must be switched off and allowed to cool and the mains plug pulled out before cleaning and chan-

ging the infrared heat lamp.

Please note that only infrared lamps of the original type may be used as replacements.

Appliance

:

Replacement infrared lamp

(type)

:

Specifications

: Lifespan

Item number:

IL 11

Infrared R95 (100 W)

230V ~ 50 Hz

4200 h

614.51

IL 21

Infrared PAR 38 (150 W)

240V ~ 50 Hz

5000 h

616.51

Warning

• Do not touch the infrared lamp or unscrew it when it is connected to the mains.

• Unplug the device, to avoid the risk of electrocution.

• In the interest of environmental protection, do not dispose of the device in household waste.

7. Cleaning and care of the unit

The unit should be cleaned occasionally.

Important

To avoid odours caused by fluff and dust, we recommend regularly cleaning the device as follows:

• The device must be switched off and allowed to cool and the mains plug pulled out before cleaning and

changing the infrared heat lamp.

• Ensure that no water penetrates inside the unit!

• Do not wash the unit in a washing machine!

Clean using a damp cloth, to which you can apply a little detergent if necessary.

• Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the

unit. The unit must be operated only when it is completely dry.

• Do not use abrasive detergents and never immerse the unit in water.

8. Disposal

In the interest of protecting the environment, the unit must not be thrown out with the household waste at the

end of its service life. Dispose of the unit at a suitable local collection or recycling point.

Please dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic

Equipment). If you have any queries, please contact the appropriate local authorities.

9. Technical specifications

Mains connection

IL 11: 220-230 V~ / 50-60 Hz; IL 21: 220-240 V~ / 50-60 Hz

Power consumption

IL 11: 100 W; IL 21: 150 W

Max. Radiation intensity

1900 W/m

2

at 380-3000 nm

Dimensions (W x H x D)

IL 11: 120 x 205 x 165 mm

IL 21: 145 x 220 x 175 mm

Weight

IL 11: approx. 320g / IL 21: approx. 600g

Operating conditions

Temperature: +5°C to +35°C; Relative humidity: 15%-93%

Storage and transport

Temperature: -25°C to +70°C; Relative humidity: ≤93%

Expected operating life of the device 7 years

Subject to technical modifications. This device meets the requirements of the European Medical Devices Direc-

tive 93/42/EEC with amendments as well as the German Medical Devices Act.