thermostatic valves

fault diagnostic

TSP431 | TSP922 | TSP934 | TSP935 | TSU431| TSU922 | TSU934 | TSU935

Problem/Symptom

Cause

Action/cure

1. Poor or no flow from shower

a) Water supplies closed

b) Shower mixer blocked

c) Blockage in pipework

d) Showerhead blocked

e) Reduced flow rate when other outlets in use

Check other outlets in property

Check inlets filters for blockages

Check pipework for blockage

Clean sprayplate or replace

Check service valves are fully open

Reduce simultaneous demand

2. Shower will not shut off

a) Debris on shut off faces

b) Shut off seals damaged / ceramic disk

damaged

Clean/replace washer

Replace headwork

3. Water too cold

a) Not enough hot water flowing through the

mixer

b) Decrease in the ambient cold water

temperature

c) Insufficient hot water delivery from the

heating appliance

d) Hot supply restricted

Turn temperature control to hotter setting

(Adjust maximum temperature setting)

Turn temperature control to hotter setting

Ensure heating appliance is set to maximum hot

water output

Check for restrictions in pipework

4. Water too hot

a) Not enough cold water flowing through the

mixer

b) Increase in the ambient cold water

temperature

c) Cold supply restricted

Turn temperature control to cooler setting

Turn temperature control to cooler setting

Check for restrictions in pipework

5. Shower varies from normal

temperature to cold during use

a) Hot water temperature has dropped below

minimum required

Wait until the hot water temperature resumes to

normal

6. Fluctuation of mixed

temperature

a) Connections inverted

b) Mixer inverted

Invert the mixer if possible or

Use a “reverse cartridge”

7. Hot water clock wise

Cold water anti-clock wise

a) Connections inverted

b) Mixer inverted

Invert the mixer if possible or

Use a “reverse cartridge”