INSTRUCTIONS FOR THE USER

It is necessary that all the operations regarding the installation, adjustment and

adaptation to the type of gas available are carried out by qualified personnel, in

conformity with the regulations in force.

The specific instructions are described in the booklet section intended for the

installer.

USING THE BURNERS

The symbols silk-screen printed on the side of the knob

indicate the correspondence between the knob and the

burner.

Start-up without valves

Turn the corresponding knob anticlockwise up to the

maximum position (large flame, fig. 1) and press.

Automatic start-up with valves

Turn the corresponding knob anticlockwise up to the

maximum position (large flame, fig. 1) and press the knob.

Once the burner has been started up, keep the knob

pressed for about 6 seconds.

Using the burners

In order to obtain the maximum yield without waste of

gas, it is important that the diameter of the pot is suitable

for the burner potential (see the following table), so as to

avoid that the flame goes out of the pot bottom (fig. 2).

Use the maximum capacity to quickly make the liquids

reach the boiling temperature, and the reduced capacity to

heat food or maintain boiling. All of the operating positions

must be chosen between the maximum and the minimum

ones, never between the minimum position and the closing

point.

Use the maximum capacity to quickly make the liquids

reach the boiling temperature, and the reduced capacity to

heat food or maintain boiling. All of the operating positions

must be chosen between the maximum and the minimum

ones, never between the minimum position and the closing

point.

The gas supply can be interrupted by turning the knob

clockwise up to the closing position.

If there is no power supply, it is possible to light the

burners with matches, setting the knob to the start-up

point (large flame, fig. 1).

BURNERS

POWER W

Ø of pots

Auxiliary

1000

10 - 14 cm

Semi-rapid

1750

16 - 18 cm

Rapid

3000

20 - 22 cm

Triple crown

3800

22 - 24 cm

Notice

- When the equipment is not working, always check that

the knobs are in the closing position (see fig.1).

- If the flame should blow out accidentally, the safety

valve will automatically stop the gas supply, after a few

seconds. To restore operation, set the knob to the lighting

point (large flame, fig. 1) and press.

- While cooking with fat or oil, pay the utmost attention as

these substances can catch fire when overheated.

- Do not use sprays near the appliance in operation.

- Do not place unstable or deformed pots on the burner, so

as to prevent them from overturning or overflowing.

- Make sure that pot handles are placed properly.

- When the burner is started up, check that the flameis

regular and, before taking pots away, always lowerthe

flame or put it out.

CLEANING

Before any operation, disconnect the appliance from the

electric grid.

It is advisable to clean the appliance when it is cold.

Enamelled parts

The enamelled parts must be washed with a sponge and

soapy water or with a light detergent.

Do not use abrasive or corrosive products.

Do not leave substances, such as lemon or tomato juice,

salt water, vinegar, coffee and milk on the enamelled

surfaces for a long time.

Stainless steel parts

Stainless steel can be stained if it remains in contact with

highly calcareous water or aggressive detergents for an

extended period of time.

The stainless steel parts should also be cleaned with

soapy water and then dried with a soft cloth.

Burners and racks

These parts can be removed to make cleaning easier.

The burners must be washed with a sponge and soapy

water or with a light detergent, wiped well and placed in

their housing perfectly. Make sure that the flame-dividing

ducts are not clogged.

Check that the feeler of the safety valve and the start-up

electrode are always perfectly cleaned, so as to ensure an

optimum operation.

Gas taps

The possible lubrication of the taps must be carried out by

specialized personnel, exclusively.

In case of hardening or malfunctions in the gas taps,

apply to the Customer Service.