Command description – Burst Electronics AS8x8 User Manual

Page 8

Advertising
background image

computer.

Command Description


Sio (Set Input Output)

This command routes an input channel specified by i
to and output channel specified by o. The i and o
characters are single digit values from 0 to 8 (0 being
channel off). There are no spaces allowed. The
command must be followed by a carriage return. The
unit switches immediately after receiving the carriage
return.

R (READ)
This command causes the AS8x8 to transmit the
current settings of all 8 audio outputs to the host
computer. No carriage return is necessary.

L (LOCK)
When received , this command locks the current
audio setting to prevent changes. Once locked the
unit will then ignore any subsequent SET commands,
and will display an appropriate error message. The
audio setting can still be viewed using the READ
command. The unit will stay in the locked mode until
as ESC (1B hex) code is received. No carriage return
is necessary.

M (MANUAL)
This command is used to place the unit in the
Triggered Manual Mode (Mode 2) from the Remote
Mode. Once initiated, the unit will remain in the
Triggered Manual Mode. To return to the remote
mode transmit an ESC (1B hex) to the unit. No
carriage return is necessary.