TC-3 SMPTE TIME CODE Generator/Reader

SMPTE Time Code Generator
Time Code Out Adjustment

B

URST

E

LECTRONICS

INC

A

LBUQUERQUE

, NM 87

109 USA

(505) 898-1455

(505) 898-0159 FAX

www.burstelectronics.com

The TC-3

An improvement has been made to the TC-3. The Output
level of the Time Code Out signal can now be adjusted.
It is preset to 0 dBm, 0.775 Vac (2 volts peak to peak).
Some VTRs (such as the Sony 9800) might require a higher
audio signal.

The adjustment control is located on the rear panel between
the two RCA jacks. Adjust as required, minimum is 0 V,
max is 1.5 Vac (4.2 Vpp).