4/ CLEANING THE HOOD

Careful maintenance helps guarantee proper operation and good results from an appliance

over time.

The hood must be unplugged from the electrical power source, both by unplugging

the appliance from the socket as well as de-activating the breaker, before removing the

metal filters. After cleaning, you must replace the metal filters as outlined in the instruc-

tions.

MAINTENANCE

HOW TO PROCEED?

ACCESSORY PRODUCTS TO

USE

External surfaces and

accessories

Do not use metallic scrub-

bers, abrasive products, or

hard brushes.

To clean the external sur-

faces of the hood and the

light housing screen use

only commercially available

household detergents dilut-

ed in water. Then rinse with

clean water and dry with a

soft cloth.

Charcoal filter with extract-

able unit open

After 30 hours of function-

ing, the downdraft will sig-

nal the grease filter satura-

tion.

The grease filter satura-

tion is signalled through

a flashing of the 4 central

leds.

The reset function is acti-

vated by pushing the timer

key while the extractable

unit is open.

The grease filters can be

washed by hand or in the

dishwasher. These filters

need to be cleaned on a reg-

ular basis because otherwise

they may present a fire risk.

Refit the grease filters and

front panel, making sure that

the panel is properly fitted at

the sides so that it does not

cause the downdraft to stop

operating.

Active carbon filter

In the recirculation mode,

you must substitute the ac-

tive carbon filter periodically.

To remove the carbon filter

it is necessary first of all to

remove the grease filter and

then to pull the plastic key of

the panel itself to remove it

from its seating.

Follow these steps in reverse

order to insert the active car-

bon filter.

Replace the used carbon fil-

ter on an average of every six

months.