5vca modules – Cloud Electronics CX233 User Manual

Page 5

Advertising
background image

4

CX233 I

NSTALLATION AND OPERATION MANUAL

4.03

Stereo/Mono Operation

All CX233's leave the factory configured for stereo operation. By configuring circuit
jumpers on the upper PCB each output zone can be configured to operate in the mono
mode.

When operating in the mono mode, the output signal is present on both left and right
output connectors and either, or both may be used.

5

VCA Modules

5.01

VCA Modules

Local control of the signal level can be achieved on all three zone outputs by fitting
optional stereo VCA modules. These compact modules utilise a pair of industry standard
low distortion VCA's and simply plug into the upper PCB adjacent to the output circuitry.
The modules can be retro-fitted but the CX233 would normally be supplied with the
modules fitted if specified at the time of ordering.

5.02

Fitting VCA Modules

1.

Before commencing any work, the CX233 must be disconnected from its power
source whether this be AC or DC.

2.

Remove the CX233 top panel.

3.

Locate the 10 pin male connector positioned adjacent to the respective output
zones. This should have each end pair of contacts shorted by single circuit
jumpers. Remove these two jumpers.

Advertising