3. Cleaning

Clean the refrigerator thoroughly at intervals, as

necessary. Remove the shelves; these, the

cabinet interior and the door should be washed with a

warm solution of sodium bi-carbonate. Finally wipe

over with a cloth rinsed in warm water only, and dry

with a clean cloth. Do not wash any plastic parts in

water that is more than hand warm, and do not expose

them to dry heat. The outside of the cabinet should be

wiped down regularly with a clean, damp cloth.
NEVER USE STRONG CHEMICALS OR ABRASIVE

CLEANING MATERIALS ON ANY PART OF THE

CABINET.

4. Positioning the appliance

When first using this refrigerator please consider the

following points:

ENSURE REFRIGERATOR IS LEVEL
THE PIPEWORK AT THE BACK GETS HOT IN USE
THE REFRIGERATOR HAS NO 'MOTOR' AND IS

THEREFORE VIRTUALLY SILENT
ALLOW AT LEAST 3 HRS. FOR SIGNS OF

COOLING

During the refrigeration process, the appliance

gives off heat from the condenser (under the

upper part of the rear cover) into the surrounding air.

The more ventilated the condenser is, the more

effective the refrigeration will be.

The other condition for satisfactory operation is that

the appliance stands on a flat surface. This is best

seen by placing a glass of water on top of the

appliance.
It is important that the appliance is not directly

exposed to radiated heat (sunlight, radiator, near an

oven, etc.).
Please do not place the refrigerator onto thick

carpet!

4.1. Installation instructions

This version is supposed to be freestanding. Cooling

unit room cover protects from the hot parts of the

cooling unit. Foot frame with grilles ensures sufficient

ventilation.

5. Using the appliance

To start the refrigerator connect the plug to the socket

outlet and switch on the socket. The cooling fins

should show signs of cooling after about 1-2 hours

depending on ambiant temperature.

5.1. Initial operation

The device must be plugged into a properly earthed

socket.
The miniCool starts automatically with a self-test.

The LED illuminates after plugging-in several times

and after that continuous light can be seen if the

door is open.

The miniCool achieves its operating temperature

after several hours.

5.2. Temperature regulation

The usual setting required is in the region of the

middle of the thermostat knob (Fig. 6), but this can

vary with conditions of load and installation. If it is

found necessary to alter the setting,the knob can

be turned to a higher symbol to produce a colder

temperature, or a lower symbol to produce a

warmer temperature. The effect of any adjustment

can be checked by means of a thermometer after

leaving the refrigerator operating for a further

period to settle down again.

Figure 3.

6. Thermometer

(Fig. 4)

Refer to the separate instruction leaflet supplied

with the thermometer. The thermometer can be

stood up using the attached stand or alternatively it

can be fixed to the refrigerator door, in which case

the sensor wire should be arranged so that it is not

stretched or damaged when the door is opened.
The temperature sensor is located inside the

refrigerator in the upper left corner in front of the

evaporator.
The display will then show the current, maximum

and minimum temperature inside the refrigerator.
After the first pull down of the refrigerator (allow

four hours) please make a "reset" on the

thermometer because otherwise it will keep as

"maximum" the ambient temperature.
If you find lower than +2 °C or even negative

temperature as a minimum on the screen, it must

have occured due to a cutout in the electrical

circuit. In these circumstance's the electronic

thermostat will make a restart and start to cool

down the refrigerator, without monitoring the

refrigerator for 45 minutes. If you reset the

thermometer again (1-2 hours later) and the normal

+2 ... +8 °C is shown then you can be sure that the

medincines have not been damaged or frozen.
The more medicines you store in the refrigerator

then reduces the hazard of freezing, if the unit has

a short period of time undercooling.
We take no responsibility for damage to

vaccines through freezing, if there has been a

cutout in the electricity for a short period of

time.
It is important to reset the thermometer regularly to

ensure that the temperature is maintained between

2 °C and 8 °C.