Updating Firmware

MN-CDM800

4–9

Once the Management IP address is known – use Command‐line to PING: Type “ping 

xxx.xxx.xxx.xxx” at the Command‐line prompt (where ‘xxx.xxx.xxx.xxx’ is the unit 
Management IP Address).  

 

The  response  should  confirm  whether  or  not  the  unit  is  properly  connected  and 
communicating. 

 
2. Use Command‐line to transfer (FTP) the files from the user PC to the CDM‐800: 

 

• Type  "ftp  xxx.xxx.xxx.xxx"  (where  ‘xxx.xxx.xxx.xxx’  denotes  the  Management  IP 

address of the unit being upgraded. 
 

• Enter  the  username  and  password  assigned  to  the  unit.  The  default  username  and 

password is “comtech”. 

 

• Type “bin” to set the binary transfer mode. 

 

• Type  "put  FW‐0000430x_CDM800.bin"  (where  ‘x’  denotes  the  revision  letter)  at  the 

Command‐line  prompt,  without  quotes,  to  begin  the  file  transfer.  The  process 
sequences  through  several  blocks  –  this  may  take  several  minutes  for  the  transfer  to 
occur. Once the upgrade file is received, the image is written to Flash memory and the 
unit transmits the message “UPLOAD COMPLETE.”  

 

 

In the event you receive the “Connection closed by remote host.” message, 
wait another minute before continuing. The CDM‐800 update sometimes 
takes longer than the FTP client allows.
 

 

• Type "bye" to terminate the FTP session, and then close the Command‐line window. 

 
3. Use the CLI or the Web Server Interface ‘Admin | Firmware’ page to verify that the PC‐to‐

Unit FTP file transfer was successful. 

 

4. Use the CDM‐800 Web Server Interface to select the firmware and reboot the unit: 
 

A. Select the desired Boot Slot (Image): 

 

• Go to the Web Server Interface ‘Admin | Firmware’ page. 

 

• Use the ‘Boot From:’ drop‐down menu 

to select LatestSlot 1, or Slot 2 (in the 
Firmware Configuration section). 

 

By default, the unit will boot from the Slot that stores the firmware version having 
the latest date (Boot From: Latest). ‘Boot From:’ may also be set to force the unit to 
boot up using either firmware image loaded in Slot 1 or Slot 2

 

• Click [Submit] to save the setting. 