Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction Code

and Qualifier)

Response to

Query

LNB LO Frequency LLO=

6 bytes

Command or Query.
LNB Receive LO frequency information in the form xxxxxs, where:
xxxxx = LO frequency, in the range of 3000 to 65000 MHz
All 0’s (000000) disables the feature.
s is the sign for the mix (+ or - character)
Terminal Frequency = LNB LO

± RFQ

Example: LLO=06000- (LO is 6 GHz, high-side mix)

LLO=
LLO?
LLO*
LLO#

LLO?

LLO=xxxxxs
(see Description of
Arguments)

LNB Power Control

LPC= 1

byte,

value of 0 thru 3

Command or Query.
LNB Power Control, where
0=Off
1=On, 13V LNB Voltage
2=On, 18V LNB Voltage
3=On, 24V LNB Voltage
Example: LPC=1 (LNB power is On, 13 volts)

LPC=
LPC?
LPC*
LPC#

LPC?

LPC=x
(see Description of
Arguments)