Upon selection of the desired input, a small popup window appears that shows all
services on the particular input. This is achieved by looking at the Program Stream
Information (PSI) that is contained in the Program Association Table (PAT) and Program
Mapping Table (PMT) – all detected programs will be displayed for either input port
selected.

Enable

Enables or disables the route.


Name

The name of the incoming program that is extracted from the Program Service
Information.


Program Number

The program number to be routed to the Ethernet as Transport Stream over IP.


PMT PID Number

The PMT PID to be routed to the Ethernet as Transport Stream over IP.


Destination IP

The IP address to be used when routing the Transport Stream over Ethernet IP.

Port Number

The Port Number to be used when routing the Transport Stream over Ethernet IP.