Comtech EF Data SPOD PS 1, PS 1.5, and PS 2 C-, X-, or Ku-Band User Manual

Page 119

Advertising
background image

SPOD C-, X-, or Ku-Band Outdoor Amplifier

MN-SPODPSX

Serial-based Remote Product Management

Revision 1

5–27

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Retrieve Next 5

Unread Stored

Events

N/A

75 bytes

Query only.

Returns the oldest 5 Stored Events which have not yet been read over the remote control in the format {CR}Sub-body{CR}Sub-

body{CR}Sub-body{CR} Sub-body{CR}Sub-body, where:

Sub-body= ABCCddmmyyhhmmss:

A being the fault/clear indicator.

F=Fault

C=Clear

I=Info

B being the fault type where:

1=Unit

2=RF

3=Log

CC is Fault Code numbers, as in RAS? or Info Code, which is:

0=Power Off

1=Power On

2=Log Cleared

3=Global Config Change

4=Redundancy Config Change

RAS fault codes map as follows:

1)

P24V1

2)

P24V2

3)

LNBVT (Not applicable on the SPOD)

4)

P13VT

5)

A10V1

6)

A10V2

7)

10VPS

8)

P5V8T

9)

P2V5T

10) P1V2T

11) N5V8T

12) P7V8T

13) FANR1

14) FANR2

15) ATEMP

16) SHTDN

17) IICST

18) FWPWR

19) CHKSM

20) FPGAD

21) BUCLD (Not applicable on the SPOD)

22) REFLD (Not applicable on the SPOD)

23) LNBCS (Not applicable on the SPOD)

24) SWITC

If there are less than 5 events to be retrieved, the remaining positions are padded with zeros.

If there are no new events, the response is RNE*.

A Global Config Change is defined as any time a command is successfully executed. A query does not set the status change.

RNE=

RNE?

RNE={CR}ABCCdd

mmyyhhmmss{CR}A

BCCddmmyyhhmms

s{CR}ABCCddmmyy

hhmmss{CR}ABCCd

dmmyyhhmmss{CR}

ABCCddmmyyhhm

mss

(See Description of

Arguments)

Advertising