Comtech EF Data CDM-IP 300L User Manual

Page 138

Advertising
background image

CDM-IP 300L IP-Centric Satellite Modem

Rev. 1

CD/CDMIP300L.IOM

112

Parameter

Type

Protocol

Description

Eb/No Status Command:

Response:

<add/EBN0_'cr'
>add/EBN0_xnn.ndB'cr''lf']

Where:

x = < or > (data modifier to indicate that the Eb/No is less than or
greater than the returned value).

nn.n = 1.0 to 99.9 (Eb/No value).

Notes: 1. The 'x' (< or >) parameter is only returned if the Eb/No

has exceeded the computational resolution of the
system.

2. 'No Data' is returned if the Eb/No cannot be
calculated.

3. 'Sampling' is returned if not enough data is currently
available to calculate the Eb/No.

Modulator
Rate Status

Command:
Response:

<add/MR_'cr'
>add/MR_nnnn_mmmm.mmm'cr''lf']

Where:.

nnnn = 1/2 (QPSK 1/2), [coder rate], 3/4 (QPSK 3/4), 7/8 (QPSK
7/8), BP12 (BPSK 1/2), 8P23 (8-PSK 2/3), (OQ12 (OQPSK 1/2),
OQ34 (OQPSK 3/4), OQ78 (OQPSK 7/8)

mmmm.mmm = Data rate in kHz

Demodulator
Rate Status

Command:
Response:

<add/DR_'cr'
>add/DR_nnnn_mmmm.mmm'cr''lf']

Where:

nnnn = 1/2 (QPSK 1/2), [coder rate], 3/4 (QPSK 3/4), 7/8 (QPSK
7/8), BP12 (BPSK 1/2), 8P23 (8-PSK 2/3), (OQ12 (OQPSK 1/2),
OQ34 (OQPSK 3/4), OQ78 (OQPSK 7/8)

mmmm.mmm = Data rate in kHz.

Receive
Signal Level
Status

Command:
Response:

<add/RSL_'cr'
>add/RSL_xsnn.ndBm'cr''lf']

Where:

x = < or > (data modifier to indicate that the receive signal level is
less than or greater than the returned value).

s = + or - (receive signal level sign, plus or minus).

nn.n = 0.0 to 99.9 (receive signal level magnitude).

Notes: 1. The 'x' (< or >) parameter is only returned if the level

has exceeded the computational resolution of the
system.

2. 'No Data' is returned if the level cannot be calculated.

3. Sampling' is returned if not enough data is currently
available to calculate the level.

LNB Current
Monitor
Status

Command:
Response:

<add/LNBC_'cr'
>add/LNBC_nnn'cr''lf']

Where: nnn = 0 to 500 (in 1 mA steps)

Notes: 1. The 'x' (< or >) parameter is only returned if the level

has exceeded the computational resolution of the
system.

2. 'No Data' is returned if the level cannot be calculated.

3. Sampling' is returned if not enough data is currently
available to calculate the level.

Advertising
This manual is related to the following products: