Efbus1/2 port (j6), 1 efbus1/2 port (j6) – Comtech EF Data SNM-1000 User Manual

Page 37

Advertising
background image

SNM-1000 Node Control Modem

Revision 3

Installation

MN/SNM1000.IOM


2–5

2.3.1

EFBUS1/2 Port (J6)

The EFBUS port provides two separate 2-wire EIA-485 interfaces wired to a common
9-pin D female connector located on the rear of the MIDAS Node Control Modem.

The

IF Modulator and IF Demodulator status is also presented for external use.

The Modem Control serial port, EFBUS1, is used for control of other Comtech EF Data
traffic modems.

The signals are described in the following table, with signal names

having the MC prefix.

The interface is ASYNC, EIA-485/2 wire, and 19.2 kbps.


The EFBUS2 port is reserved for communication with future MIDAS traffic modems.


Signal Function


Name

I/O

MIDAS

Conn Pin #

Signal

Level

Ground MCGND

-

1

-

Demodulator fault

BP_DF

I/O

2

TTL

Modulator fault

BP_MF

I/O

3

TTL

Receive/Transmit +

MS_RD/SD+(EFBUS2)

I/O

4

EIA-485

Receive/Transmit -

MS_RD/SD-(EFBUS2)

I/O

5

EIA-485

Receive/Transmit+ MC_RD/SD+(EFBUS1) I/O

6

EIA-485

Receive/Transmit- MC_RD/SD-(EFBUS1) I/O

7

EIA-485

Ground MSGND

-

8

-

Not used

-

-

9

-

Not used

-

-

-

-