1 redundancy controller error states, 3 main menu ( maintenance status, 3 main menu æ maintenance status – Comtech EF Data CiLink User Manual

Page 32

Advertising
background image

CSAT-5060/XSAT-7080 Transceiver iPAQ Link

Revision 2

Operations

MN/CiLink.IOM

3–10

3.3.2.5.1

Redundancy Controller Error States

If the user attempts to configure the Redundancy Controller when
CiLink has been set up for standalone operation, the following error
message displays:



If the user has set up the CiLink system for 1:1 system operations in
the absence of a redundant system installation, the following error
message displays:

3.3.3

Main Menu

Æ Maintenance Status

The currently selected transceiver is the unit that will be polled for
status information in the

Maintenance Status XCVR#

selection box:


XCVR1

is the default selection and

XCVR2

is not selectable if CiLink is set to operate under

standalone (non-redundant) system parameters (see

Configuration

Æ

System Type

for detailed

information).




XCVR Internal Voltages

– The transceiver unit monitors the

six internal DC voltages: 24, 20, 12, 10, +5 and –5. The
voltages are displayed for the currently selected transceiver.

Tuning (Volts)

– The transceiver monitors the four tuning

voltages that are variable depending on frequency.

Currents (mA)

– The cooling fan and the LNA currents are

displayed in milliamps.

Temperatures

– The Up Slice and Down Slice temperatures

are displayed in degrees C.

RF Power (dBm)

– The actual RF output power of the Up

Converter is displayed in dBm.


Tap

[Get Data]

to

query

the selected transceiver and

refresh

the information parameters.

Otherwise, tap

[ok]

to

eturn

to the

Main Menu

from the

Maintenance Status

screen.

IMPORTANT

The information provided on the Maintenance Status screen furnishes
information on a
status only basis. All information furnished on this screen is
refreshed each time the
Maintenance Status screen is selected, if the currently
selected transceiver is changed, or if the

[Get Data]

icon is selected.

Advertising