LPOD-R Outdoor Amplifier / Block Up Converter (BUC)

MN-LPODR

Optional Serial-based Remote Product Management

Revision 1

5–16

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to

Query

(Target to

Controller)

Retrieve next

5 unread

Stored

Alarms

E

(cont)

Example: <1/LNA?’cr’

>0001/LNA=’cr’

LOG CLR IF 175503 052307’cr’

FAN #1 FT 175504 052307’cr’

OVR TMP FT 175504 052307’cr’

FAN #1 OK 175504 052307’cr’

IIC BUS FT 175504 052307’cr’’lf’

Notes:

1) If there are no events in the log the unit will reply with LNA*.

2) All events that are read from the log are also automatically removed from the log.

Low forward

Power

Threshold

LPT=

5 bytes

Command or Query.

Sets or returns the threshold for the low forward power alarm/fault in the form xx.xx.

Default Value: 00.00

Example: <1/LPT=00.00’cr’

>0001LPT=’cr’’lf’

Notes:

1) If there are no events in the log the unit will reply with LNA*.

2) All events that are read from the log are also automatically removed from the log.

3) Setting this parameter to 00.00 effectively disables the threshold

LPT =

LPT?

LPT *

LPT?

LPT =xx.xx

(Same format as

command

arguments)

Local/Remote

State

LRS=

1 byte

Command or Query.

Sets or returns the Local or Remote state for the Indoor SSPA in the form x, where:

0 = Local

1=Serial

2=Ethernet

3=Serial+Ethernet

Default Value: 3 (Serial+Ethernet)

Example: <1/LRS=3’cr’

>0001/LRS=’cr’’lf’

Notes:

1) Use this command to limit changes from being made on multiple interfaces at the same time.

2) State is always in remote mode for Outdoor SSPAs such as the LPOD-R.

3) The LRS command is available in all modes as a means of acquiring control. You will always have query access in

any mode.

4) The LPOD-R treats LRS=0 as reserved, and refuses the command by returning a mode error.

5) The Web server interface is inoperable unless LRS is set to enable Ethernet remote control.

LRS=

LRS?

LRS?

LRS=x

(Same format as

command

arguments)

Advertising