Scpc step up threshold, Scpc step down threshold, Scpc step delay – Comtech EF Data CDM-570/L Vipersat Parameter Editor User Manual

Page 62

Advertising
background image

Vipersat

2-46

CDM-570/L, CDD-56X Parameter Editor User Guide

Note: Load switching must be enabled on all CDM-570/570Ls in a network in

order for the VMS to utilize load switching when dynamically optimizing

network performance as load conditions change.

If the application rate is less than the load, the VMS will not switch. It will,

however, set up SHOD (Single Hop on Demand) if the application

requires it.

Application switching by the VMS (such as Voice and/or Video) is not

affected by this setting. However, using Load switching for real-time

applications is not recommended.

The appearance of parameters for Load Switching will differ, depending on

whether the unit is configured as a Hub or as a Remote.

SCPC Step Up Threshold

Appears for Remote modems only.
The SCPC Step Up Threshold field establishes the percentage of bandwidth

use that will trigger a switch up from the present SCPC rate to a higher rate to

ensure that there is sufficent bandwidth available for current conditions. Valid

range is from 65 to 100 %.
Typically, the default value will be acceptable, but this value can be changed to

accommodate a unique network configuration or application. Note that this

value must be greater than the value specified for the SCPC Step Down Thresh-

old (see below).

SCPC Step Down Threshold

Appears for Remote modems only.
The SCPC Step Down Threshold field establishes the percentage of band-

width use that will trigger a switch down from the present SCPC rate to a lower

rate to ensure efficient bandwidth usage. Valid range is from 1 to 95 %.
Typically, the default value will be acceptable, but this value can be changed to

accommodate a unique network configuration or application. Note that this

value must be less than the value specified for the SCPC Step Up Threshold (see

above).

SCPC Step Delay

Appears for Remote modems only.
The SCPC Step Delay field allows a switching delay period to be specified to

ensure that a premature switch up or down in the SCPC rate does not occur due

to a temporary rise or fall in traffic.