Initial Configuration

The procedure for setting the modem configuration to match the defined

network role is presented later in this Quick Start (“Set the Vipersat Configura-

tion” on page 2-10).
Refer to the section “Unit Role” on page 3-38, and the following section

“Expansion Unit”, for additional details on setting a CDD-56X’s network role.

Setting Vipersat CDD-56X Operating Parameters

The following is an example of using the CLI to bring a Vipersat CDD-56X

with factory default settings to the configuration which allows the Vipersat

functions to be accessible.

Set the Feature Configuration

The operating parameters that will be configured in the target CDD-56X are, in

part, determined by the role the CDD-56X is to fill in the network, as shown in

table 2-1 and table 2-2.
Use the following procedure to configure a CDD-56X to the network role it is to

fill in a Vipersat network.

1.

From the Main Menu shown in figure 2-1, select the Administration

command by entering A at the command prompt.

Table 2-1 CDD-56X Network Roles and Functions

Demod

Role / Location

Expansion

1

2

3

4

Hub

No

STDMA

SCPC

SCPC

SCPC

Hub

Yes

SCPC

SCPC

SCPC

SCPC

Remote

Yes

SCPC

SCPC

SCPC

SCPC