Comtest Networks NID-01V POTS Splitter User Manual

You should have, Choosing a mounting location

Advertising
background image

Rev 2-0 July. 2009

Page 1 of 2

Residential NID-01V POTS Splitter Installation Guide

Copyright © 2009,

Comtest Networks Inc.


This guide provides the basic information required to install the NID-01V POTS Splitter in a Telephone Network
Interface location. Qualified personnel must perform the installation of the NID-01V POTS Splitter.

Planning Installation

You should have

• Nut driver wrench suitable to remove/tighten the bolts used in the Telephone Network Interface box.

• Suitable wire for the installation (22AWG, 24AWG or 26AWG solid conductor type), and

• Wire

cutters


CAUTION - To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord/cable.

Choosing a Mounting Location

The NID-01V is designed to be mounted in the Telco side of the Telephone Network Interface (SNI) box.

The orientation of the NID-01V is important as it should be positioned to provide easy access to the IDC
connectors on the top of the unit

It is required that the NID-01V is installed after a suitable protection device. Comtest recommends the use of a
capacitively balanced protection block in order to ensure that optimum system performance is achieved and
maintained.

Correct Wiring

Customer Access side

Telephone Company Access side

NID-01V

Telephone Network
Interface box