gned for the type and diameter of the connection pipe

used, and screwed joints should be sealed with a joining

compound approved for use with bottled gas.

The gas supply pipe should be connected to the gas inlet

pipe on the right hand side of the gas control valve by

means of a suitable threaded compression coupling.

In making the connection to the refrigerator, a union gas

cock of an approved type bottled-gas must be incorpora-

ted in the supply line in a position which is readily acces-

sible to the user. For eventual servicing purposes, the

union should be on the outlet side of the cock and the

pipework should be positioned so as not to prevent the

refrigerator from being readily withdrawn.

ELECTRICAL CONNECTION 230VAC

Check that the voltage stated on the data plate is the

same as the mains voltage in use (230 V).

Plug the 230 V refrigerator power cord into an easily

accessible wall socket.

Electrical leads must be routed and secured

so that they cannot come into contact with hot

or sharp parts of the refrigerator.

12 V Supplies

Connect the refrigerator to the vehicle battery by a direct

cable. To avoid a voltage drop, the cross sectional area

of the connecting cable between battery and refrigerator

must be at least 2.5 mm² if the distance is less than 9

meters, and at least 4 mm² if the distance is more than 9

meters. To ensure satisfactory operation, the positive

lead must be fitted with a fuse rated at max. 16 A.
To prevent the refrigerator from draining the battery,

make sure that the current supplied to the caravan is cut

off when the vehicle engine is not running, for example

by fitting an ignition control relay.

Diagramme for the mains installation: FIG.1

Diagramme for the 12 V installation: FIG.2

The notations in the wiring diagramme are:

A. Electronic igniter/reigniter

B. Electrode (at burner)

C. 12 V heating element

D. Switch for 12 V operation

E. Switch for reigniter (gas op.)

F. Electric thermostat

G. Heating element, 240 V

H. Switch for 240 V operation

J. Terminal block

L. Terminal block

12 V supply of reigniter

FIG.2 shows the wiring diagramme of the refrigerator as

delivered. The 12 V supply enters at (L). The reigniter (A)

is fed via two wires (1) and (2) at terminal block (L).
It is advisable to feed the reigniter and the lighting from a

separate 12 V source. To do this: remove the wires (1)

and (2) and connect the supply as is shown in FIG.3.
In some executions there in an extra terminal block (J),

of FIG.2. In this case one disconnects the wires as

said above but connects the separate supply to

(J).The reigniter should not be connected directly

to a battery charger but only over a battery.