8 troubleshooting, Scoreboard will not light – Daktronics Single Section DistaView Outdoor LED Scoreboards Generation IV User Manual

Page 41

Advertising
background image

5-6

Scoreboard

Maintenance

and Troubleshooting

Description

Daktronics Part No.

15" LED Digit

0P-1192-0308

18" LED Ones Digit

0P-1192-0304

24" LED Horizontal

Segment

0P-1192-0305

24" LED Vertical Segments

0P-1192-0306

5.8 Troubleshooting

This section lists potential problems with the scoreboard and indicates possible
causes and corrective actions. This list does not include every possible problem, but
does represent some of the more common situations that may occur.

Symptom/Condition

Possible Cause

Scoreboard will not light

ƒ

Console not connected or poor connection

ƒ

No power to control console

ƒ

No power to the scoreboard

Garbled display

ƒ

Internal driver logic malfunction

ƒ

Control console malfunction

Digit will not light

ƒ

Black wire to digit broken

ƒ

Poor contact at driver connection.

ƒ Driver

malfunction

Segment will not light

ƒ

Broken LED or connection

ƒ

Driver shift register failure

ƒ

Broken wire between driver and digit

ƒ

Poor contact at driver connector

Segment stays lit

ƒ

Driver shift register failure

ƒ

Short circuit on digit

Date appears in the wrong

place on the scoreboard

ƒ

Incorrect address settings on drivers (consult

tables and set correct addresses)

5.9 Daktronics Exchange and Repair and

Return Programs

To serve customers’ repair and maintenance needs, Daktronics offers both an
Exchange Program and a Repair and Return Program.

Advertising