Daktronics Ethernet Switch Enclosure User Manual

Ethernet switch enclosure installation quick guide, Primary 1 - front view primary 2 - rear view j32, J32 j33

Advertising
background image

Ethernet Switch Enclosure Installation Quick Guide

PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128

tel: 800-325-8766 fax: 605-697-4700

www.daktronics.com

DD1946340 Rev 1

13 December 2012

Applications

When two primary displays are installed within 25 feet of each other, use the Ethernet switch enclosure to

eliminate the need for a second communications kit.

Mounting

The Ethernet switch enclosure must be within 25 feet of the communication box. If using more than two

primary displays, the Ethernet switch enclosure can be daisy chained to a total of three Ethernet switch

enclosures. All display IP addresses must be different. Refer to attached drawing, DWG-1043135, for

additional information

1. Mount the Ethernet switch enclosure between the displays and ensure the cables exit the bottom

of the enclosure.

2. Connect the Ethernet quick connect cable from the communications enclosure to J10 on the

Ethernet switch enclosure.

3. Connect the 6-pin quick connect cable from the communications enclosure to J9 on the Ethernet

switch enclosure.

4. Route the Ethernet and 6-pin quick connect from the Ethernet switch enclosure to J32 and J33

jacks on one of the displays.

5. Connect the Ethernet cable from the Ethernet switch enclosure to J32 on the back of the display.

6. Connect the 6-pin to J33 on the back of the display.

7. Connect the Ethernet quick connect cable from the Ethernet switch enclosure to J32 on the second

display.

Primary 1 - Front View

Primary 2 - Rear View

J32

Comm. Box

Ethernet Switch

Ethernet

6-Pin Power

Must be Less Than 25 Feet

Must be Less

Than 25 Feet

J10

J9

J32

J33

Figure 1: Power and Signal Routing from the Ethernet Switch to the Displays

Advertising