Daktronics Rear-Ventilated GalaxyPro GP3 and GP4 Display User Manual

Rear-ventilated galaxypro, Gp3 and gp4 display installation quick guide, Step 1: display mounting

Advertising
background image

Rear-Ventilated GalaxyPro

®

GP3 and GP4 Display Installation Quick Guide

DD1931894 Rev 05

21 Ocotober 2014

PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128

tel: 800-325-8766 fax: 605-697-4700

www.daktronics.com

Step 1: Display Mounting

Refer to Section 3 of display manual for additional

information.

Note: For Multi-Section Displays – See reverse side of this
document for section splicing instructions.

1. Lift the display into position on support structure. Refer

to label at
lift eyes for
information.
• Maintain a

55-degree
or greater
angle
between
display
and lift
straps.

• Do not

adjust or
remove
lift eyes.

• Do not lift display in wind speeds greater than 20

mph.

2. Weld or bolt ALL T-clips to support structure.

Note: T-clips can be adjusted within the guidelines of the
label located at each T-clip.

Angle must be

greater than 55°

L

T-CLIP CAN BE ADJUSTED BUT MUST FALL BETWEEN LINES

Complete these steps in order during the installation process.

Step 2: Power Installation

Refer to Section 5 of display manual or shop drawing for

additional information.

1. Open power entrance.

2. Connect conduit to 2” Myers hub on the left side of the

power entrance located on back of display.

3. Connect primary power lines to appropriate taps in

enclosure – refer to label on enclosure for wiring
diagram.

4. Reinstall power

entrance cover.

5. Connect grounding

electrode to ground
lug on each section.

Step 3: External Cable Installation

Refer to Section 7

of display manual

for additional

information.

Note: Refer to label
on back of display
for cable routing.

1. Install fiber

quick-connect
cables between
display sections
when applicable.

2. Install fiber quick-

connect cable
between Primary
and Mirror
display faces
when applicable.

Note: Remove protective cap from cables.

Step 4: Communications Installation

Refer to communications manual or section 8 in display

manual for additional information.

1. Mount display communications enclosure (wire Ethernet,

fiber Ethernet or radio) according to guidelines in
communications manual.

2. Route quick-connect cables from enclosure to Primary

display quick connect.

3. Connect cables to quick-connect on back of display.

4. Make interior connections to customer’s network or

directly to control computer.

Step 5: Turn Display On

Observe boot sequence shown on the display to get the IP
Address or DHCP name.

Note: Boot time is approximately 3 minutes.

Step 6: Venus 1500 Software

Configuration

Refer to Section 9 of display manual for additional

information.

1. Click Start > All Programs > Daktronics > Venus

1500 V4 to verify Venus 1500 is installed on the control
computer.

2. Click Application button > Configure > Displays to

launch the display configuration wizard in Venus 1500..

3. Click Add Display.

4. Select the customer’s display from the list and click

Continue.

5. Enter the customer’s password on the Authentication

Page. Click Continue. The default password for GP4
displays is

DakPassword!.

6. Name the display. Click Continue.

7. Select the correct time zone for the display’s location.

8. Click Finish in the Summary window. The new display

appears in the Display Management window.

9. Close the Display Management window to return to the

Home tab view.

Advertising