Installation

1. Mount the display into the sign structure using the provided holes in the mounting

flange. Refer to

Figure 1 and Figure 2.

Note: Do not drill holes into the display face. This will void the warranty.

2. Use appropriate screws or other hardware to secure the sign to the structure.

Note: The display is front ventilated. Do
not block the display face in any way.
This may void the display warranty.

Power Connection

1. Use the provided knockouts on the back

of the display for power entrance.

2. Use a flat-head screwdriver to turn the latches and access the interior of the

display.

3. Connect the primary power hot (black) and neutral (white) wires to the wires

coming from the power supply. Refer to

Figure 3.

Note: Refer to the display shop drawing for power requirements.

4. Connect the primary power ground (green) wire to the ground bar next to the

power supply.

Display Interconnections

Signal travels from the host driver jack J9 to additional
display drivers through the Line-to-Line cable. Line-to-line
connections are made using jacks J9 and J10 on the driver.

The preferred cable routing has signal leaving each driver
from jack J9 and entering the next driver on jack J10

Each time you connect the line-to-line cable to J9, you

must also connect the drain wire to the upper-left stud

that holds the driver in place.

1. Use provided knockouts on the back of the display for

signal entrance and exit. Refer to

Figure 4.

2. Install the provided bushing at the knockout location.

3. Connect the provided line-to-line cable, shown in Figure 5, to host driver jack J9. The host driver can be identified by

having the communication option attached to jack J16.

Figure 1: Securing Digit Cabinet

daktronics

CORNER GAS

UNL

REG

DSL

Figure 2: Inserting Digits into
Cabinet

Ground (Green)

Hot

(Black)

Neutral (White)

Power Supply

Driver

Figure 3: Power Wiring

Line 2

Line 3

Line 1

2

3

1

Signal Wire

Figure 4: Line-to-Line Details

Figure 5: Line-to-Line Cable

Advertising