Daktronics Configuring the DM-100 for Generic Interface User Manual

1 preparation, 2 configuration, 3 changing prices

Advertising
background image

Configuring the DM-100 for Generic Interface

page 1 of 2

DD1750101 Rev 0

3 February 2010

PO Box 5128 201 Daktronics Drive, Brookings, SD 57006-5128

tel: 866-343-3122 fax: 605-697-4700

www.daktronics.com

1.1 Preparation

The DM-100 function must be set to GAS PRICE. The current function of the DM-100 is
displayed during power up. To change the function, cycle power to the DM-100, and press the
SET FUNCTION key when prompted.
Note: The cable used to connect the DM-100 and POS system is supplied by the customer.

1.2 Configuration

LCD Screen

Action

POS SETTINGS
ENT TO MODIFY

↓↑

POS INTERFACE
GENERIC

↓↑

LINE 1
PRODUCT: 0001 *

LINE PRICE
1

$X.XX 9/10

POS CONTROLLED
1

$X.XX 9/10

Press the MENU key and use the



and

‚

keys

to scroll to the POS SETTINGS menu item. Press

ENTER.

Select the POS type by using the



and

‚

keys to

scroll to Generic. Press ENTER.

Each price in Generic is uniquely identified by a

product ID. Use the



and

‚

keys to select a

grade for the line. (If a line is not used, select

NONE. Press ENTER.

Select a corresponding product ID for each display

line. When this menu is reached, all lines have

been configured. The POS interface configuration

is complete.

Currently configured prices will be shown in the

format shown at left.

1.3 Changing Prices

Each display line for which a price category is configured will automatically update when the
price is changed in the POS system. Attempting to manually edit prices that are configured for
POS control will cause the following screen to appear:

LCD Screen

Action

THIS LINE POS
CTRLD. OVERRIDE?

To manually edit the price, press ENTER. To

cancel, press CLEAR. To continue, press ENTER.

1.4 Troubleshooting

Verify communication from DM-100 to sign:

Advertising