Installing an rj connector, Conduit, Installing an rj connector -4 – Daktronics AF-3180-64-R,A User Manual

Page 24: Conduit -4, Figure 18: flipped cable with rj connectors, Figure 19: wire with outer jacket stripped, 4 conduit

Advertising
background image

Figure 18: Flipped Cable with RJ Connectors

Installing an RJ Connector

Installing an RJ connector on the end of the conductor cable is a simple task when
the correct tools are used. The RJ crimping tool (Daktronics part number TH-1033)
performs two separate steps

Figure 19: Wire with Outer
Jacket Stripped

First, use the crimping tool to strip the outer insulation from
the inner wires. This does not result in bare wires since only
the gray outer jacket is removed. After correct stripping, the
wire will appear as shown in Figure 19 on the right.

The crimping tool is then used to crimp the RJ connector
onto the cable. The RJ connector is locked into a special
socket in the tool. The stripped wire is inserted into the RJ
connector. Finally, the tool is squeezed like pliers to crimp
the connector onto the wire. This completes the installation
of an RJ connector onto the wire.

3.4 Conduit

Reference Drawings:

Shop Drawings ....................................................................... Appendix A

Daktronics does not include the conduit. Refer to the Shop Drawing for approximate
locations of power and signal conduit. You must use separate conduit to route:

Power

Signal IN wires

Signal OUT wires (if another sign requires signal)


Locate the conduit holes at the bottom right (rear view) of the back of the sign.
Refer to Shop Drawings for appropriate locations.

Punch or drill out the desired conduit openings. Be careful not to damage any
internal components. Attach the conduit, and then route the power and signal cables.

For displays with more than one face, a quick connect cable is provided to connect
the output on the first display to the input on the second.

If the displays are not back-to-back or are too far apart for the quick connect cable,
other cables for signal and the temperature sensor wiring can be used. In that case,
the same conduit can be used between displays to route the signal cables.

Electrical Installation

3-4

Advertising