Front view side view top view, Isometric rear view, Adetail a scale 1:32 – Daktronics Sportsound 500HD User Manual

Page 36

Advertising
background image

14

DISPLAY

LENGTH

(FT.)

16

18

20

25

28

32

36

A

(FT)

B

(FT)

TABLE 2

4'-9"

6'-3"

5'-0"

7'-0"

5'-3"

7'-9"

5'-6"

8'-6"

6'-10"

9'-8"

7'-4"

10'-8"

7'-0"

13'-0"

6'-10"

15'-4"

3'-6"

DEPTH

SS500HD

WT: 850LBS

DISPLAY LENGTH

8'-0"

LENGTH

B

B

A

GRADE

2'-9"

22" MAX.

SIDE PANEL

SIDE PANEL

DISPLAY

HEIGHT

GRADE

DISPLAY HEIGHT IS MADE UP OF

ANY COMBINATION OF SCOREBOARDS,
AD PANELS, TRUSSES, AND MESSAGE

CENTERS.

FRONT VIEW

SIDE VIEW

TOP VIEW

(STRUCTURE ONLY)

HSS4X4X3/16

OPTIONAL SUPPORT FOR
SIDE PANEL MOUNTING.

FOR SPACING SEE TABLE 2.

TUBES TO BE CUT FLUSH WITH
THE BACK OF THE HORIZONTAL

STRINGER.

FOR STRINGER SIZE

REFER TO DAKTRONICS DRAWING:

1561-E10B-982267

VARIOUS

DISPLAYS

GRADE

0' 0"

MAX. HEIGHT

40' 0"

FOR SIDE AD/TRUSS ATTACHMENT TO TUBE
REFER TO DAKTRONICS DRAWING:

1348-E10B-1111650.

STRINGER

LENGTH

12'-11"

14'-5"

15'-11"

17'-5"

19'-9"

21'-9"

26'-5"

31'-1"

3'-0"

FRONT OF HORIZ. TUBE FLUSH

WITH FRONT OF THE COLUMNS.

INSET W4X13 VERTICAL BEAM
1/4" FOR WELD.

NOTES:

1.0 REFERENCE
1.1 REFER TO DAKTRONICS DRAWING: 1561-E10B-969776 FOR

SPORTSOUND 500HD ENGINEERING SPECIFICATIONS.

1.2 REFER TO DAKTRONICS DRAWING: 1561-E10C-982267 FOR

SPORTSOUND 500HD MOUNTING DETAILS AND RECOMMENDED
STRINGER SIZE.

1.3 REFER TO DAKTRONICS RISER DIAGRAM FOR ALL ELECTRICAL

POWER AND DATA SPECIFICATIONS.

1.4 THE SHOWN SYSTEM IS PROVIDED TO ASSIST WITH

ESTIMATING INSTALLATION COSTS AND ARE NOT INTENDED FOR

CONSTRUCTION PURPOSES. THE DESIGN MUST BE CERTIFIED BY A

PROFESSIONAL ENGINEER LICENSED IN THE STATE OF THE
INSTALLATION BEFORE THEY CAN BE USED FOR FABRICATION OR
ERECTION.

2.0 GENERAL NOTES
2.1 ALL DIMENSIONS ARE IN FEET AND INCHES.
2.2 REFER TO INSTALLATION AND MAINTENANCE MANUAL FOR
COMPLETE INSTALLATION INSTRUCTIONS.

3.0 SOUND CABINET NOTES
3.1 DAKTRONICS SOUND CABINET IS STEEL CONSTRUCTED
SKELETON WITH ALUMINUM PANELING FASTENED TO ITS

EXTERIOR.

3.2 LIFTING POINTS ARE PROVIDED BY DAKTRONICS. WHEN

SYSTEM. ALIGN LIFT EYES WITH CABLES.
3.3 REMOVE SHIPPING BRACKETS FROM TOP OF CABINET. 3.4

PAINT COLOR:

SPEAKER CABINET COLOR: POWDER COAT BLACK.

4.0 STRUCTURAL NOTES
4.1 FABRICATION AND ERECTION SHALL CONFORM TO THE LATEST

EDITION OF AISC SPECIFCATIONS.

4.2 ALL WELDING (SHOP AND FIELD) SHALL BE PERFORMED IN
ACCORDANCE WITH AWS D1.1-LATEST EDITION SPECIFICATIONS

BY A CERTIFIED WELDER USING E70XX ELECTRODES.

4.3 INTERNATIONAL BUILDING CODE 2006 USED IN DESIGN OF

SPORTSOUND CABINET SUPPORT MEMBERS WITH, IMPORTANCE

FACTOR=1, Kzt=1.0, Kd=0.85, G=0.85, Cf=1.8, z=40ft AND EXPOSURE

C. SEISMIC DESIGN WAS NOT CONSIDERED.

4.4 THE DESIGN WIND PRESSURES WERE SHIFTED AND ADJUSTED
TO ACCOUNT FOR ASCE 7 PRESCRIBED OFFSET EFFECTS.
4.5 ALL STRUCTURAL STEEL SHALL BE ASTM A36

(36 KSI) EXCEPT:

- WIDE FLANGE SHALL BE A992 (50 KSI) STEEL

- TUBING SHALL BE A500-B (46 KSI)
4.6 ALL OPEN TUBE ENDS SHALL BE CAPPED AND WELDED ALL
AROUND.

THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON THIS

DRAWING ARE CONFIDENTIAL AND PROPRIETARY. DO NOT
REPRODUCE BY ANY MEANS WITHOUT THE EXPRESSED

WRITTEN CONSENT OF DAKTRONICS, INC.

COPYRIGHT 2011 DAKTRONICS, INC.

DAKTRONICS, INC.

BH

DRAWN:

DATE:

SHEET

JOB NO:

REV

DAKTRONICS AUDIO SYSTEMS - SPORTSOUND 500HD
SIDE PANEL MOUNTING DETAILS W/ SS500HD

DTREML

22 MAR 10

P 1561

E 10 B

3/16"=1'

MSHRESTHA

992088

04

DATE:

REV

BY:

01

9 JUN 11

MBJ

UPDATED SIDE VIEW

27

7'-2"

10'-4"

21'-1"

DATE:

REV

BY:

02

10 FEB 12

KCS

ADDED 27' DISPLAY TO TABLE

500HD CABINET MOUNTING TUBES

REFER TO DAKTRONICS DRAWING:

1561-E10B-982267

DATE:

REV

BY:

03

23 APR 12

JLR

REPLACED HSS VERT TUBES WITH W4X13
FOR AD PANEL MOUNTING

DATE:

REV

BY:

04

23 JAN 13

KCS

MADE OPTIONAL SUPPORT TUBES FOR AD PANELS
FLUSH WITH THE REAR OF THE HORZ STRINGER

ISOMETRIC REAR VIEW

SS500HD W/ SIDE AD

MOUNTING TUBES & BEAMS

SS500HD

ALL TUBES SHALL

BE CAPPED.

CUT TOP OF VERTICAL SUPPORT STEEL (3'-0")

TO BE FLUSH WITH TOP OF

SIDE PANEL IF REQUIRED.

A

DETAIL A

SCALE 1:32

HSS4X4X3/16

SUPPORT FOR SS500HD

AND SIDE PANEL MOUNTING.

TYP.

3/16

TYP.

W4X13 FOR SIDE AD

PANEL MOUNTING.

Advertising