Configuration Settings

Charge Profiles Available:

Conventional Charge IUIa/IEI
Opportunity Charge
Fast Charge (battery module required)

Battery Types:

Flooded, Sealed, Gel.

Environments:

Standard, Freeze/cold condition.

Cable Length:

Combined charger and battery cable length in metres.

Equalize Charge Settings:
Cycle count:

Adjustable to any number. Default setting is to equalize
charge after every 5 complete charge cycles.

Day/time:

Select day and time of the week to trigger an equalize charge
on the next charge cycle. Can also select to have it equalize
charge every other week.

Manual equalize: Select to have an equalize charge run from the display panel.

Contact your local Eco Charge / Dealer for assistance with the adjustment
of these settings.

Ampere-Hour Ranges:

FS5

FS9

Low limit (Ahr)

Upper Limit (Ahr)

Low limit (Ahr)

Upper Limit (Ahr)

Conventional Profile (16A/100Ahr)

24V

300

1875

300

3375

36V

300

1875

300

3375

48V

300

1575

300

2810

Opportunity Profile (25A/100Ahr)

24V

300

1200

300

2160

36V

300

1200

300

2160

48V

300

1000

300

1800

Fast Profile (40A/100Ahr)

24V

300

750

300

1350

36V

300

750

300

1350

48V

300

625

300

1125