Bargrp, Bar wt – Digi-Star RD 4000 User Manual

Page 4

Advertising
background image

RD

4000

The RD4000 displays only alphanumeric characters and
annunciators on EZ 150, EZ 210 and EZ 320 indicators.

Bar Graph Mode

With EZ software revision 5.A or greater the bar graph is
functional and can be set to the following settings:

Menu #2

BARGRP

– (D.A.N. 236)

0 = OFF.

1 = Display from “left to right” for Presets and
Timer/Counter only.

2 = Display from “left to right” for Presets, Timer/Counter &
Gross Full Scale Weight.

3 = Display from “right to left” for Presets and
Timer/Counter only.

4 = Display from “right to left” for Presets, Timer/Counter &
Gross Full Scale Weight.

Menu # 2

BAR WT

(D.A.N. 237)

Enter the Gross Full Scale Weight to activate all LED’s of
the bar graph.

This is used with Bar Graph Modes 2 and 4.

EXAMPLE: If set to a weight value of 12,000, half of the bar
graph will be lit when the gross weight displayed is 6,000.