Digi-Star EZ2500 User Manual

Page 19

Advertising
background image

Menus and Calibration

D3895-US Rev A

EZ2500 User’s Manual

15

SETTING

[display]

D.A.N

NO.

OPTIONS [displayed]

BOLD=DEFAULT

DESCRIPTION

ANALOG HIGH

WEIGHT

(HIGHWT)

242

Enter analog weight value to

equal 20mA or 5 volts

ANALOG SELECT

(ANAOUT)

243

Select 0-5V,4-20ma or 0-20ma

output

MENU 3. SCALE CALIBRATION SETTINGS

DISPLAY UNIT

(lb-kg)

301

.01,.02,.05,.1,.2,.5,1,2,5,

10

,20, 50,100

Select display count size of

weigh values.

CAPACITY

(cap)

303

LB

/KG

Display pounds -lb or

kilograms -kg

WM1 ADJUST 1

(wmaI-I)

304 40000

Enter MAXIMUM weight

measurable on scale.

MENU 4. PRESET, BATCHING & ROTATION COUNTER FEATURES

Does not apply to 2500 indicator

CALIBRATION

DEAD WEIGHT

CAL

(CAL)

802

Calibration method using

weights

SETUP NUMBER

(SETUP)

871

Quick entry method selects

weigh method 1-4lbs, 5-8 kg,

gain 1-9, display counts 1-9

and capacity *1000

CALIBRATION

NUMBER

(CAL)

872

Weight displayed at 0.4mV/V

for these load cells

Advertising