v. MAINTeNANCe

Unplug the battery charger from the appliance before any maintenance. Store the vacuum

cleaner at a dry place, far enough from heat sources (e.g.

fireplace, stove, heating

element) and protect it against weather conditions (e.g. rain, sunshine). Treat the surface

of the vacuum cleaner and the battery charger (only when disconnected from the electric

socket) with a soft and wet cloth, do not use abrasive and aggressive cleaning agents! Never

dry plastic moldings over a heat source (e.g.

heater, electric/gas stove).

Floor nozzle with rotation brush

After any vacuuming it is recommended to check visually the brushes or collectors for possible

impurities. If you find some impurities, remove them in the way specified below. Cut threads

and hair with scissors and remove them. If hair or threads are twisted around the mounting of

the drive shaft and if they cannot be removed in the way described above, the impurities have

to be removed by dismantling the nozzles. Unscrew the bolt in the lower part and remove the

cover (Fig. 5). Bend the locking cog with a suitable tool (e.g. a flat screwdriver). Now you can

remove the brush from its position and clean it. Insert the brush to the nozzle in the opposite

direction (you will hear a snapping sound) and secure it properly with a lid.

Storage

Store the appliance thoroughly clean on a dry, dustless place out of reach of children and

persons sui juris. The accessories may be stored in the back of the charging stand

C or in

the storage space

C1 (Fig. 6). Do not put the assembled rod vacuum cleaner on an uneven

surface! The cleaner must be placed on a flat surface where there is no danger of knocking

over.

VI. TROUBLESHOOTING

Problem

Cause

Solution

Motor won‘t start

The battery is discharged
A1/B1

button is not

switched on

Recharge the battery
Push A1/B1 button

The container

cannot be fixed

to the vacuum

cleaner

The parts of the filtration

system not inserted

properly in the container

Check/correct insertion of the

protector and the micro-filter in the

container

Suction output is

not sufficient

Dust container full
Clogged filter protector
Clogged micro-filter
The accessories are

clogged
The battery is discharged

Empty the container

Clean the protector
Clean or replace the micro-filter
Remove blocking objects

Recharge the battery

Nozzle with

rotation brush

does not work

Rotation brush is blocked

Remove blocking objects

25